APPENDICES
Symptom
The E22 error was output
even after I checked the set-
ting on the DIP switch and
cycled the power supply.
An error message (E∗∗)
appears.
A-10
Probable cause
There is noise on a signal
line.
There is noise on the power
supply line to the H8PS or
encoder.
The Encoder is faulty.
Corrective action
Attach ferrite cores to the signal lines.
Change the path of the signal lines.
Separate the cables from power lines.
Attach a ferrite core to power supply line on the AC
input or DC output side.
Disconnect the FG line.
Ground the FG to a different location.
Change the path of the power supply line.
Separate the cables from power lines.
Replace the Encoder.
Refer to "Appendix B Troubleshooting"