Omron H8PS Operation Manual page 120

Cam positioner
Hide thumbs Also See for H8PS:
Table of Contents

Advertisement

APPENDICES
■ Problems during Preparatory Steps/Initial Setting
Symptom
None of indicators is lit.
After turning the power on,
all indicators are lit for too a
long time.
The display angle does not
match the actual angle of the
encoder.
An E2
error suddenly
occurs although the encoder
is rotating at a low speed.
Although the DIP switch set-
ting has been changed, the
new setting is not effective.
The movement is not smooth
although the encoder has
been replaced with another
with the same resolution
The angle decreases. (The
rotation display monitor turns
counterclockwise.)
Switching to the function set-
ting mode is not possible.
Some angle display values
are skipped.
A-6
Probable cause
Power is not supplied cor-
rectly.
Power on operation immedi-
ately after changing the DIP
switch setting (changing the
encoder resolution setting)
The DIP switch resolution
setting does not match the
resolution of the encoder.
The power has not been
cycled.
The origin has shifted.
The direction of rotation set-
ting is incorrect.
The programming mode is
not selected.
The bank number display is
flashing (16-/32-output mod-
els only).
The [ADV] key is not held
down long enough.
A 256 resolution/rotation
(360° notation display)
encoder is used.
Corrective action
Check if the power cables are connected to the
power supply terminals correctly and also if the
power supply voltage is correct.
In this case, the processing time is longer (by
approx. 3 seconds) than for normal processing.
In normal processing, i.e., when the DIP switch
setting has not been changed, the H8PS Cam
Positioner starts running after approximately one
second.
Correct the DIP switch setting (encoder resolution)
to match the encoder to be connected.
Refer to "3.3.1 Selecting the Encoder Resolution"
The H8PS Cam Positioner reads the DIP switch
setting when the power is turned on. To make the
new setting effective, cycle the power.
Refer to "3.3 DIP Switch Setting"
When the encoder is replaced, the origin must be
set again.
Refer to "3.4 Setting the Origin"
Set the direction of rotation correctly with the DIP
switch.
Refer to "3.3.2 Setting the Rotation Direction"
After setting the mode switch to PRGM, hold the
[ADV] key down for at least three seconds.
No key operation is accepted while a bank is not
identified. Select a bank by pressing the [WRITE]
key.
Refer to "4.8.3 Designating the Bank Using the
Keys"
Hold the [ADV] key down for at least three sec-
onds, until "F1" appears in Main display.
Since the encoder angle is converted to 360° nota-
tion to display, some angle values are not dis-
played.
Refer to "Appendix E Angle Data Table (256 Reso-
lution)"