Section 4 HOW TO USE THE ADVANCED FUNCTIONS
● Precautions on using the step number limit function
Before setting the step
number limit function
Setting "2" as the limit of
step numbers
4-22
Before setting the step number limit function, make sure that a
program has not been set for the target cam.
If this function is set without due care as in the case shown below, a
cam program that cannot be checked in the programming mode could
run.
0
1
20° ON
70° ON
30° OFF
90° OFF
20° ON
70° ON
30° OFF
90° OFF
Programming is possible
for up to 2 steps only (Step
No. 0 and No. 1).
Program addition is
not possible.
Step No.
2
...
8
...
...
The output turns ON since this
has been included in the
program. (This step cannot be
checked in the program check
operation.)
9
200° ON
230° OFF
200° ON
230° OFF