Advertisement

5.7

Other instructions

5.7.1

Sequence program stop (STOP)

STOP
STOP
Setting
Data
––
Function
(1) Resets the output (Y) and stops the CPU module operation when the execution command is
turned ON.
(The same result will take place if switch is turned to the STOP setting.)
(2) Execution of the STOP instruction will cause the value of b4 to b7 of the special register
SD203 to become "3".
(3) In order to restart CPU module operations after the execution of the STOP instruction, return
switch, which has been changed from RUN to STOP, back to the RUN position.
Command
Internal Devices
R, ZR
Bit
Word
b15
to
b12
SD203
High
Basic
performance
J
\
U
\G
Bit
Word
––
b11
to
b8
b7
to
b4
b3
to
b0
0 0 1 1
Sets value "3".
STOP
Process
Redundant Universal
LCPU
STOP
Zn
Constants
Other
5-55
1
2
3
4
5
6
7
8