Data Transfer Instructions - Mitsubishi MELSEC Q Series Programming Manual

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

6.4

Data Transfer Instructions

6.4.1
16-bit and 32-bit data transfers (MOV(P),DMOV(P))
MOV(P),DMOV(P)
MOV, DMOV
MOVP, DMOVP
Setting
Data
S
D
Function
MOV
(1) Transfers the 16-bit data from the device designated by
Before transfer
After transfer
DMOV
(1) Transfers 32-bit data at the device designated by
Before transfer
After transfer
Operation Error
(1) There are no operation errors associated with the MOV(P) or DMOV(P) instruction.
Command
Command
: Data to be transferred or the number of the device where the data to be transferred is stored (BIN 16/32 bits)
S
: Number of the device where the data will be transferred (BIN 16/32 bits)
D
Internal Devices
R, ZR
Bit
Word
b15
S
1
0
1
1
0
1
0
b15
D
1
0
1
1
0
1
0
S
+1
b15
S
1
0
1
1
0
1
D
+1
b15
D
1
0
1
1
0
1
High
Basic
performance
indicates an instruction symbol of
J
\
U
\G
Bit
Word
to the device designated by
S
0
0
1
1
1
0
0
1
Transfer
0
0
1
1
1
0
0
1
to the device designated by
S
S
b0
b15
0
0
0
1
1
1
0
Transfer
D
b0
b15
0
0
0
1
1
1
0
MOV(P),DMOV(P)
Process
Redundant Universal
LCPU
MOV/DMOV.
S
D
P
S
D
Constants
Zn
Other
K, H
––
––
––
D
b0
0
b0
0
.
D
b0
0
1
0
b0
0
1
0
6-107
1
2
3
4
4
6
7
8
.