Mitsubishi MELSEC Q Series Programming Manual page 827

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Program Example
(1) The following program outputs the lower four bits of data in R66 to R69 to Y30 through Y3F
in units of 4 points.
[Ladder Mode]
Before execution
(source of transfer)
b15
R66
R67
R68
R69
Ignored
(2) The following program outputs the data in X20 to X2F to R100 to R103 in units of 4 points.
[Ladder Mode]
X2F X2C
Before
1
execution
After execution
(destination of transfer)
b4
b3
b0
1
1 1 0 1
1
0
0 0 0 0
0
1
0 0 1 1
0
0
1 1 0 1
1
X2B X28
X23
X20
X27 X24
0
0 0
0 1 1 1
0 1 1 0
0 1 0 0
b15
0
0
0
0
[List Mode]
Step
Instruction
1
0
1
Y33 to Y30
0
0
0
Y37 to Y34
0
1
1
Y3B to Y38
1
0
1
Y3F to Y3C
[List Mode]
Step
Instruction
After execution
(destination of transfer)
b4
b3
b0
0
0 0
0 0 0 0
0 0 0 0
0 1 0 0
R100
0
0 0
0 0 0 0
0 0 0 0
0 1 1 0
R101
0
0 0
0 0 0 0
0 0 0 0
0 1 0 0
R102
0
0 0
0 0 0 0
0 0 0 0
1 0 0 0
R103
Filled with 0s
RBMOV(P)
Device
Device
4 points
7-453
1
2
3
4
6
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec l series

Table of Contents