EXP(P)
7.12.21
Exponent operation on floating-point data
(Single precision) (EXP(P))
EXP(P)
EXP
EXPP
Setting
Data
S
D
Function
(1) Returns the exponent of the value designated by
at the device designated by
(2) Exponent operations are calculated taking the base (e) to be "2.71828".
7-290
Basic model QCPU: The upper five digits of the serial No. are "04122" or larger.
Command
Command
: Data of which the exponential value is obtained or head number of the devices where the data is stored
S
(real number)
: Head number of the devices where the operation result will be stored (real number)
D
Internal Devices
R, ZR
Bit
Word
––
––
.
D
S
+1
S
e
(
32-bit floating-point
real number
Ver.
High
Basic
performance
EXP
EXPP
J
\
U
\G
Bit
Word
––
––
*1: Applicable for the Universal model QCPU, LCPU.
, and stores the results of the operation
S
D
+1
D
)
32-bit floating-point
real number
Process
Redundant Universal
LCPU
S
D
S
D
Constants
Zn
Other
E
*1
––
*1
––
––

Hide quick links: