(S(P).DEVLD)
Operation Error
(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and
an error code is stored into SD0.
• The address specified at n1 is out of the standard ROM range.
• The number of n2 points from the address specified at n1 is out of the standard ROM
range.
• The range for the number of n2 points from the device
device.
• The device data storage file is not set at "PLC file" of PLC parameter on GX Developer.
Program Example
(1) The program which reads the ten points of data from D100 to the device data storage file in
the standard ROM when M0 turns ON.
[Ladder Mode]
7-442
exceeds the corresponding
D
[List Mode]
Step
Instruction
(Error code: 4100)
(Error code: 4100)
(Error code: 4101)
(Error code: 2410)
Device