 Pattern of storage in unit memories (UM)
• Set data is stored in 8-word blocks of corresponding unit memories in the following format.
• When using user programs, set data in corresponding unit memory numbers.
Example 1) For the comparison data 0 of CH0, it is allocated to UM00080 to UM00087.
Example 2) For the comparison data 1 of CH0, it is allocated to UM00088 to UM0008F.
• The bit numbers 0 to 15 in the area of +4 in the figure below correspond to the comparison
match 0 flag to F flag.
Lower limit Low words
Lower limit High words
Upper limit Low words
Upper limit High words
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
REFERENCE
For details of unit memory numbers, refer to 11.4 Unit Memory Detailed
Specifications.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Not used
Not used
Not used
Lower limit
Upper limit
0
Set pattern
Reserved for system
1:ON, 0:OFF