7.2.3 Configuration of Target Value Match Comparison

 Overview of setting items
• For each comparison data, specify whether to set or reset each flag when the current value
matches the target value.
• Multiple comparison match flags can be set for one comparison data.
• Different flag operations can be set depending on the count direction when the values are
matched (at the time of addition or subtraction).
Comparison data 0
Comparison data 15
Setting for Target value match comparison
 Example of settings by FPWIN GR7
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Comparison data 0
Addition set pattern 0
Addition reset pattern 0
Subtraction set pattern 0
Subtraction reset pattern 0
Comparison data 15
Addition set pattern 15
Addition reset pattern 15
Subtraction set pattern 15
Subtraction reset pattern 15
Comparison match 0 flag
to
Comparison match F flag

Advertisement