PAR02
TTL multiplying factor (subdivision). Independent for each axis.
Options: x4, x2, x1 and x0.5.
The factory setting is x4 and it is the one used for FAGOR linear encoders.
When using rotary encoders on linear axes, it should be calculating according
to the number of pulses of the encoder, leadscrew pitch and the desired
resolution as per the formula:
Where:
PAR03
External multiplying factor when using distance-coded reference marks or
TTL signals.
Independent for each axis. It is not required when using absolute feedback.
Options: 1, 5, 10, 20, 25, 50.
Factory setting: 1
Signal
TTL dif.
Note:
In the table, X means that the bit is irrelevant.
p = Pulses per turn of the encoder
P = Leadscrew pitch in mm/turn
R = Resolution in mm/pulse
F = Multiplying factor to be applied.
PAR00
Model
XXXXXXXX
MT / MKT
TTL
CT
FT
MTD
MX / MKX
CX
SX
GX
0000000X
FX
LX
MOX
COX
SOX
GOX
FOX
LOX
V0703-20i-M / 30i-M - Installation/Operation - DRO installation - (29/40)
P
p
=
--------- -
RxF
Feedback parameters
PAR01
PAR02 PAR03
mm
0.005
4
0.001
PAR14
X
00X0XX00
5
00X00010
25
00X01010
10
00X00110