2.7.3.2 Recall and Reset modes

RECALL mode
PRESET mode
Example
Toggles between the recall and Preset modes.
The recall mode lets enter the current axis position into the calculator.
Enters the current position of the selected axis into the calculator.
The preset mode lets preset the desired axis with the result of an operation.
Presets the selected axis with the result of the calculation.
Calculate [Y position] / 5 and preset the Y axis with the result.
Display
keys
X = 25
Y= 10
Z = 16
X = 0
Y= 0
Z = Ad
X = 10
5
Y= 0
Z = Ad
X = 10
3 times
Y= 0
Z = Ad
X = 10
Y= 5
Z = di
X = 2
Y=
Z = di
X = 2
Y= Preset
Z =
X = 25
Y= 2
Z = di
V0703 - 20i-M / 30i-M - Installation/Operation - DRO operation - (19/40)
Operation
Goes into calculator mode
Goes into RECALL mode
and enters the current
position in the Y axis.
Presets the divisor (5)
Selects the divide operation X = 10
Result in the X display (2)
Goes into Preset mode
Presets the Y axis with the
result of the calculation.
Quits the calculator mode.
Display
X = 0
Y= 0
Z = Ad
X = 10
Y= 0
Z = Ad
X = 10
Y= 5
Z = Ad
Y= 5
Z = di
X = 2
Y=
Z = di
X = 2
Y= Preset
Z =
X = 25
Y= 2
Z = di
X = 25
Y= 2
Z = 16