7.6.7 Select automatic return to the initial display [b164]
If you do not manipulate the operator for 10 minutes, the operator screen automatically changes to the
screen that you set in the (b038).
This function is enabled by setting the b164 = 01.
Item
Automatic return to the initial
display
7.6.8 NES1-OP display selection [b150]
NES1-OP key does not work when you connect an digital operator or remote operator.
This function sets the monitor code to be displayed in NES1-OP.
Item
NES1-OP display selection
7.6.9 Data Read/Write selection [b166]
This function is to choose whether to allow read / write of data in the WOP.
Item
Data Read/Write selection
See section 7.6.2
7.6.10 Display limitation function (DISP)
To use this function, assign function "86" (DISP) to one of the terminal [1] to [5] functions (C001 to C005).
While the (DISP) input is ON , the operator displays a parameter chosen by initial-screen selection. And
cannot select other parameter.
Item
Terminal [1] to [5] functions
Function code
Data
00
b164
01
Function code
Data
b150
001 to 050 d001 to d050 corresponding to the monitor item
Function code
Data
00
b166
01
Function code
Data
C001 to C005
86
7 - 47
Chapter 7 Explanation of Functions
Description
Disable
Enable
Description
Description
Enable
Disable
Description
DISP: Display limitation function