Hitachi NES1-004SB Quick Reference Manual page 66

Ne-s1 series
Table of Contents

Advertisement

(3) Method to perform driving in FW/RV teraminal and perform frequency setting in volume resistor
This is the operation method using Run command is given by intelligent input terminal such as
FW(RV) function & Frequency setting is given by analog input such as O-L voltage. If you don't
need to change such as Accel&Decel time, optional Operator is not required.) Below diagram is to
set the external Freq. setting connecting H-O-L volume to supply O-L voltage.
■Setup
Function Name
Frequency source
Run command source
Input [1] function
Input [2] function
The initial value of Acceleration/ Deceleration time is 10sec.
Please change the following parameters as needed.
Function Name
Acceleration time
Deceleration time
* One of the following is required when changing parameters on NE-S1 series inverters.
a) Dedicated operator (NES1-OP) b) Digital operator c) 5-line LCD operator
d) Modbus e) PC programming tool (ProDriveNext)
■Control circuit terminals wiring (Sink logic)
H
O/OI
L
Frequency setting
resistor
Note)
The above is a method to perform
analog input(O/OI) by voltage input. It
is necessary for SW6 on the board to
be set for voltage input(default). →
Code
A001
A002
C001
C002
Code
F002
F003
2
1
L
PLC
P24
RV
FW
Data
01(Control circuit terminals)
01(Control circuit terminals)
00(FW)
01(RV)
Setting Range
0.00 to 3600 sec.
0.00 to 3600 sec.
6 - 13
Chapter 6 Operation
Note
Default
Default
Default
Note
Default:10 sec.
Default:10 sec.