13.1 Digital Operetor
Digital Operator prepares NES1-OP,OPE-S/SR/SBK/SRmini and WOP. NES1-OP can be attached to
the NES1 inverter.Other than it,be the connection with the cable.
13.1.1 Attention at the time of the data setting
・When Function code display restriction(b037) are set other than "00" (all indication), some functions are
not displayed.
・When Software lock mode selection (b031) is validly set, cannot change the parameter.
・The function of "-" cannot change a column of "Run Mode Edit" while driving.
・It becomes modifiable mode while driving when I establish Software lock mode selection (b031) in "10"
13.1.2 Monitoring mode (Display of NES1-OP,OPE-S/SR/SBK/SRmini)
・The initial state displays (d001) at the time of power activation by all means. When you fix it by any
display, please change setting of (b038).
Func.
Name
Code
Output
d001
frequency
monitoring
Output current
d002
monitoring
Rotation
d003
direction
monitoring
PID feedback
d004
monitoring
Intelligent input
d005
terminal status
Intelligent input
d006
terminal status
Scaled output
d007
frequency
monitoring
Output voltage
d013
monitoring
Input power
d014
monitoring
Cumulative
d015
power
monitoring
Cumulative
operation RUN
d016
time
monitoring
Cumulative
d017
power-on time
monitoring
Heat sink
d018
temperature
monitoring
"d" Function
Description
0.00 to 99.99/100.0 to 400.0 (Hz)
0.0 to 655.3 (A)
F(forward rotation) / o(stopped) /
r(reverse rotation)
0.00 to 99.99/100.0 to 999.9/1000. to
9999./1000 to 9999(10000 to 99990)/
「100 to 「999(100000 to 999000)
ON
(Example)
terminal 1,2 : ON
OFF
5
4
3
2
1
terminal 3 to 5 : OFF
ON
(Example)
OFF
terminal 11 : ON
relay 11
terminal relay : OFF
0.00 to 99.99/100.0 to 999.9/
1000. to 9999./1000 to 3999
0.0 to 600.0(V)
0.0 to 999.9(kW)
0.0 to 999.9/1000. to 9999./
1000 to 9999(10000 to 99990)/
「100 to 「999(100000 to 999000)
0. to 9999./
1000 to 9999(10000 to 99990)/
「100 to 「999(100000 to 999000)(hr)
0. to 9999./
1000 to 9999(10000 to 99990)/
「100 to 「999(100000 to 999000)(hr)
-020. to 120.0(℃)
Run