Chapter 12 Specifications
Common specification
Item
Protective housing
(JIS C 0920,IEC60529)
Control method
Output frequency range Note4)
Frequency accuracy Note5)
Frequency setting resolution
Volt./Freq. characteristic
Overload capacity
Acceleration/deceleration time
Freq. setting
RUN/STOP Order
Intelligent input terminal
Analog input
Intelligent output terminal
Pulse Output
RS-422
RS-485
Temperature
Note6)
Humidity
Vibration
Location
Standards Compliance
Note1)
The applicable motor refers to Hitachi standard 3-phase motor (4p). When using other motors, care must be taken to
prevent the rated motor current (50/60Hz) from exceeding the rated output current of the inverter.
Note2)
The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case,
the output voltage cannot exceed the input power supply voltage.
Note3)
The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from
50/60Hz as indicated). It is not continuous regenerative braking torque. The average deceleration torque varies with
motor loss. This value decreases when operating beyond 50Hz.
Note4)
To operate the motor beyond 50/60Hz, consult the motor manufacturer for the maximum allowable rotation speed.
Note5)
To get motor stabilized operation, inverter output Frequency might exceeds preset maximum Freq.(A004/A204) by 2Hz in
maximum.
Note6)
Derating curve is shown on section 12.3.
Note7)
Connecting work on RJ45 jack must be done during the inverter power off.
Note8)
"*" changes by Restricted Distribution.
IP20
Sinusoidal Pulse Width Modulation (PWM) control
0.1 to 400 Hz
Digital command: 0.01% of the maximum frequency
Analog command: 0.4% of the maximum frequency (25C  10C)
Digital input: 0.01 Hz
Analog input: Maximum output frequency/1000
V/f control (constant torque, reduced torque)
150%/60 seconds
0.00 to 3,600.0 seconds (in linear or curved pattern)、2nd motors setting is possible
External signal:adjustable resistor / 0 to +10 VDC /0 to 20 mA,
Modbus、Option operator、Dedicated operator
External digital input signal(3-wire input possible), Modbus
Option Operator、Dedicated Operator
5terminals
1terminal( O/OI terminal:Voltage input10bit/0 to 10V, Current input:10bit/0 to 20mA
selecting it with a changeover switch)
5 open-collector output terminals, 1 relay (1c-contact) output terminal
1terminal
RJ45 Connector ,(Common with RS485:selecting it with a changeover switch)Option
Operator,ProDriveNext
RJ45 Connector ,( Common with RS422:selecting it with a changeover switch)
Modbus-RTU
Operating (ambient): -10 to 50C, / Storage: -20 to 65C
20 to 90% humidity (non-condensing)
2
5.9m/s
(0.6G), 10 to 55 Hz
Altitude 1,000m or less, indoors (no corrosive gasses or dust)
UL、CE、c-UL、c-tick
12 - 2
Spec