Input Function Summary Table – This table shows all thirty-four intelligent input functions at a glance.
Detailed description of these functions, related parameters and settings, and example wiring diagrams are
in "Using Intelligent Input Terminals" on page 4-8.
Option
Terminal
Code
Symbol
00
FW
01
RV
02
CF1 *1
03
CF2
04
CF3
06
JG
07
DB
08
SET
09
2CH
11
FRS
12
EXT
13
USP
15
SFT
18
RS
20
STA
21
STP
22
F/R
Input Function Summary Table
Function Name
ON
FORWARD
Run/Stop
OFF
ON
Reverse Run/Stop
OFF
Multi-speed Select,
ON
OFF
Bit 0 (LSB)
Multi-speed Select,
ON
OFF
Bit 1
Multi-speed Select,
ON
OFF
Bit 2(MSB)
ON
Jogging
OFF
ON
External DC braking
OFF
ON
Set (select) 2nd
Motor Data
OFF
ON
2-stage Acceleration
and Deceleration
OFF
ON
Free-run Stop
OFF
ON
External Trip
OFF
ON
Unattended Start
Protection
OFF
ON
Software Lock
OFF
ON
Reset Inverter
OFF
Start
ON
OFF
(3-wire interface)
Stop
ON
OFF
(3-wire interface)
ON
FWD, REV
(3-wire interface)
OFF
Description
Inverter is in Run Mode, motor runs forward
Inverter is in Stop Mode, motor stops
Inverter is in Run Mode, motor runs reverse
Inverter is in Stop Mode, motor stops
Binary encoded speed select, Bit 0, logical 1
Binary encoded speed select, Bit 0, logical 0
Binary encoded speed select, Bit 1, logical 1
Binary encoded speed select, Bit 1, logical 0
Binary encoded speed select, Bit 2, logical 1
Binary encoded speed select, Bit 2, logical 0
Inverter is in Run Mode, output to motor runs at jog
parameter frequency
Inverter is in Stop Mode
DC braking will be applied during deceleration
DC braking will not be applied
The inverter uses 2nd motor parameters for
generating frequency output to motor
The inverter uses 1st (main) motor parameters for
generating frequency output to motor
Frequency output uses 2nd-stage acceleration and
deceleration values
Frequency output uses standard acceleration and
deceleration values
Causes output to turn OFF, allowing motor to free
run (coast) to stop
Output operates normally, so controlled deceleration
stop motor
When assigned input transitions OFF to ON, inverter
latches trip event and displays
No trip event for ON to OFF, any recorded trip
events remain in history until reset
On power up, the inverter will not resume a Run
command (mostly used in the US)
On power up, the inverter will resume a Run
command that was active before power loss
The keypad and remote programming devices are
prevented from changing parameters
The parameters may be edited and stored
The trip condition is reset, the motor output is turned
OFF, and power up reset is asserted
Normal power-ON operation
Starts the motor rotation
No change to present motor status
Stops the motor rotation
No change to present motor status
Selects the direction of motor rotation: ON = FWD.
While the motor is rotating, a change of F/R will start
a deceleration, followed by a change in direction
Selects the direction of motor rotation: OFF = REV.
While the motor is rotating, a change of F/R will start
a deceleration, followed by a change in direction
13 - 51