Hitachi NES1-004SB Quick Reference Manual page 254

Ne-s1 series
Table of Contents

Advertisement

Note) Mark "" in [ Run Mode Edit] shows the accessible parameters when b031 is set "10", high level access.
Func.
Code
(WOP)
F001
(Set
Output frequency setting
Frequency)
F002
Acceleration time (1)
(Accel.time1)
F202
Acceleration time (1),
(Accel.time1-
M2)
F003
Deceleration time (1)
(Decel.time1)
F203
Deceleration time (1),
(Decel.time1-
M2)
F004
(RUN key
Keypad RUN key routing
direction)
"F" Function
Name
Description
Standard default
target frequency
that determines
constant motor
speed, range is
frequency to
frequency (A004)
Standard default
acceleration,
range is 0.00 to
3600.00 seconds.
nd
2
motor
Standard default
deceleration,
range is 0.00 to
3600.00 seconds.
nd
2
motor
Two options;
select codes:
00Forward
01 Reverse
Run
Mode
Edit
0.00 / start
maximum
13 - 25
Chapter 13 Option
Defaults
Initial data
Initial data
Initial data
standard
CHN
EU
200/400
200/400
200/400
0.00
10.00
10.00
10.00
10.00
00
Units
Hz
s
s
s
s

Hide quick links: