Function name
No.
142Ah (Reserved)
Frequency arrival setting for
142Bh
accel.
142Ch (Reserved)
Frequency arrival setting for
142Dh
decel.
142Eh PID deviation level
142Fh to
(Reserved)
1437h
1438h
Maximum PID feedback data
1439h
Minimum PID feedback data
143Ah to
(Reserved)
1440h
1441h
Electronic thermal warning level
1442h
(Reserved)
1443h
Zero speed detection level
1444h
Heat sink overheat warning level
1445h to
(Reserved)
1449h
144Ah Selection of OPE/Modbus
144Bh Communication speed
144Ch Modbus address
144Dh (Reserved)
144Eh Communication parity
144Fh Communication stop bit
Selection of the operation after
1450h
communication error
1451h
Communication timeout limit
1452h
Communication wait time
1453h to
(Reserved)
1454h
1455h
[O/OI] input span calibration
1456h to
(Reserved)
145Eh
145Fh Debug mode enable
1460h to
(Reserved)
1468h
Chapter 8 Communication Functions
Function
R/W
Monitoring and setting items
code
-
-
-
C042
R/W 0 to 40000
-
-
-
C043
R/W 0 to 40000
C044
R/W 0 to 1000
-
-
-
C052
R/W 0 to 1000
C053
R/W 0 to 1000
-
-
-
C061
R/W 0 to 100
-
-
-
C063
R/W 0 to 10000
C064
R/W 0 to 110
-
-
-
C070
R/W 0 (OPE) / 1(Modbus)
4(4800bps), 5(9600bps), 6(19.2kbps),
C071
R/W
7(38.4kbps)
C072
R/W 1. to 247.
-
-
-
0 (no parity), 1 (even parity), 2 (odd
C074
R/W
parity)
C075
R/W 1 (1 bit), 2 (2 bits)
0 (tripping), 1 (tripping after
decelerating and stopping the motor), 2
C076
R/W
(ignoring errors), 3 (stopping the motor
after free-running), 4 (decelerating and
stopping the motor)
C077
R/W 0 to 9999
C078
R/W 0 to 1000
-
-
-
C081
R/W 0 to 2000
-
-
-
C091
R
0/1
-
-
-
8 - 37
Data
resolution
-
0.01 [Hz]
-
0.01 [Hz]
0.1 [%]
-
0.1 [%]
0.1 [%]
-
1 [%]
0.01 [Hz]
1 [°c]
-
-
-
-
-
-
-
0.01 [s]
1 [ms]
-
0.1
-
-
-