Hitachi NES1-004SB Quick Reference Manual page 188

Ne-s1 series
Table of Contents

Advertisement

Chapter 8 Communication Functions
Register
Function name
No.
1375h to
(Reserved)
1384h
Deceleration over voltage
1385h
suppression enable
1386h
Decel. over volt. suppress level
1387h
Decel. over volt. suppress const.
Decel. overvolt. suppress
1388h
propotional gain
Decel. overvolt. suppress Integral
1389h
time
138Ah to
(Reserved)
1398h
1399h
Display ex.operator connected
139Ah to
(Reserved)
13A2h
1st parameter of Dual
13A3h
Monitor
2nd parameter of Dual
13A4h
Monitor
13A5h (Reserved)
Freq. set in monitoring
13A6h
Automatic return to the initial
13A7h
display
13A8h Ex. operator com. loss action
13A9h
Data Read/Write select
13AAh to
(Reserved)
13B6h
Initialization trigger
13B7h
13B8h to
unused
1400h
Function
R/W
Monitoring and setting items
code
-
-
-
0 (disabling), 1 (enabling), 2 (enabling
b130
R/W
with acceleration), 3(when Const/Dec)
200 V class: 330 to 390 (V)
b131
R/W
400 V class: 660 to 780 (V)
b132
R/W 10 to 3000
b133
R/W 0 to 500
b134
R/W 0 to 1500
-
-
-
1 to 60h(BCD) (d001 to d060)
b150
R/W
[exe. 15h : d015]
-
-
-
1 to 18h(BCD) (d001 to d018)
b160
R/W
[exe. 15h : d015]
1 to 18h(BCD) (d001 to d018)
b161
R/W
[exe. 15h : d015]
-
-
-
b163
R/W
0 (disabling), 1 (enabling)
b164
R/W
0 (disabling), 1 (enabling)
0 (tripping), 1 (tripping after
decelerating and stopping the motor), 2
(ignoring errors),
b165
R/W
3 (stopping the motor after
free-running),
4 (decelerating and stopping the motor)
b166
R/W 0 (Read/Write OK) / 1 (Protected)
-
-
-
0 (disabling), 1 (enabling)
b180
R/W
-
-
Inaccessible
8 - 34
Data
resolution
-
-
1 [V]
0.01 [s]
0.01
0.1 [s]
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links: