(2) Automatic torque boost
When automatic torque boost (data "01") is selected by the torque boost selection (A041/A241), the
inverter automatically adjusts the output frequency and voltage according to the load on the motor.
(During actual operation, the automatic torque boost is usually combined with the manual torque boost.)
When you select the automatic torque boost, adjust the settings of the motor capacity selection
(H003/H203) and motor pole selection (H004/H204) according to the motor to be driven.
If the inverter trips due to overcurrent during motor deceleration, set the AVR function select (A081) to
always enable the AVR function (data "00").
If you cannot obtain the desired operation characteristic by using the automatic torque boost, make the
following adjustments:
Symptom
Motor torque is insufficient at low
speed.
(The motor does not rotate at low
speed.)
The motor speed falls when a load
is applied to the motor.
The motor speed increases when a
load is applied to the motor.
The inverter trips due to overcurrent
when a load is applied to the motor.
7.5.3 3-wire interface operation function (STA, STP, and F/R)
The 3-wire interface operation function allows you to use automatic- reset contacts (e.g., pushbutton
switches) to start and stop the inverter.
Specify "01" (control circuit terminal block) for the run command source setting (A002).
Assign function "20" (STA), "21" (STP), and "22" (F/R) to three of the terminal [1] to [5] functions (C001 to
C005) to enable the control operations described below. Assigning the STP function to an intelligent input
terminal disables the functions of the FW and RV terminals.
While the (STP) is OFF , the (STA) is invalid.
Item
Terminal [1] to [5] functions
STA
STP
F/R
Output frequency
Adjustment method
(1) Increase the voltage setting for manual torque boost
step by step.
(2) Increase the slippage compensation gain for
automatic torque boost step by step.
(3) Increase the voltage compensation gain for
automatic torque boost step by step.
(4) Reduce the carrier frequency setting.
Increase the slippage compensation gain for the
automatic torque boost step by step.
Reduce the slippage compensation gain for the
automatic torque boost step by step.
(1) Reduce the voltage compensation gain for the
automatic torque boost step by step.
(2) Reduce the slippage compensation gain for the
automatic torque boost step by step.
(3) Reduce the voltage setting for the manual torque
boost step by step.
Function code
Data
C001 to C005
ON
OFF
ON
Forward
rotation
Reverse
rotation
7 - 23
Chapter 7 Explanation of Functions
20
STA: Starting the motor
21
STP: Stopping the motor
22
F/R: Switching the motor operation direction
OFF
Note : In 3 wire input , STP input is
Adjustment item
A042/A242
A047/A247
A046/A246
b083
A047/A247
A047/A247
A046/A246
A047/A247
A042/A242
Description
used at the b point of contact.
But the setting of STP is the a
point of contact..