Chapter 6 Operation
(2) Method to perform driving in RUN/STOP/RESET key and perform frequency setting in volume
resistor
This is the operation method using Run command is given by "RUN/STOP/RESET key" &
Frequency setting is given by analog input such as O-L voltage, Accel&Decel time is 10 seconds. (If
you don't need to change such as Accel&Decel time, optional Operator is not required.) Below
diagram is to set the external Freq. setting connecting H-O-L volume to supply O-L voltage.
■Setup
Function Name
Frequency source
The initial value of Acceleration/ Deceleration time is 10sec.
Please change the following parameters as needed.
Function Name
Acceleration time
Deceleration time
* One of the following is required when changing parameters on NE-S1 series inverters.
a) Dedicated operator (NES1-OP) b) Digital operator c) 5-line LCD operator
d) Modbus e) PC programming tool (ProDriveNext)
■Control circuit terminals wiring (Sink logic)
H
O/OI
Frequency setting
resistor
Note)
The above is a method to perform
analog input(O/OI) by voltage input. It
is necessary for SW6 on the board to
be set for voltage input(default). →
Code
A001
01(Control circuit terminals)
Code
Setting Range
F002
0.00 to 3600 sec.
F003
0.00 to 3600 sec.
L
PLC
P24
Data
default:10 sec.
default:10 sec.
6 - 12