Oil Maintenance Of The Inner Set Unit - Shimano Nexus Inter-8 Dealer's Manual

Table of Contents

Advertisement

„ Oil maintenance of the inner set unit
• In order to maintain proper performance of the product, it is
recommended that you ask the place where you purchased
the bicycle or your nearest Pro shop to carry out
maintenance such as greasing the internal parts about once
every two years from the first time of use (once about every
5,000 km if the bicycle is used very frequently). It is also
recommended that you use the Shimano internal hub grease
or lubrication kit when carrying out maintenance. If the
special grease or lubrication kit is not used, problems such as
gear shifting malfunction may occur.
1
Fill the bottle with WB oil to a
height of 95mm.
3
Keep the internal unit immersed as illustrated for
approximately 90 seconds.
5
Let the excess oil drain off for approximately 60 seconds.
2
95mm
Immerse the internal unit into the oil from the left side.
Immerse until the oil reaches up to ring gear unit 1.
4
Remove the internal unit from the oil.
6
After lubrication is complete, reassemble by following the
usual procedure.
36
WB maintenance oil set
Y00298010
Ring gear
unit 1