6.10. "THE EQUIPMENT IS BLOCKED" MESSAGE ON THE
DISPLAY
Th s error message can be caused by:
i
• loss of communication between the lower and upper assem
• interruption of the power supply to the inv
• the inverter has detected an error condition, causing it to generate an alarm and store the error
code in memory.
WARNING: if the digital plan board detects an error condition during the tread belt
motor movement, it displays the error message and turns off the inverter by de-
energizing the relay which isolates the power supply to the inverter.
Carry out the "Inv erter
Error" troubleshooting
procedure
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
Carry out the procedure for testing the serial communications described in paragraph 6.1.1.3
(1)
"Inverter Test".
To reinstate communications between the lower and upper assemblies:
(2)
• check that the wiring of the various cables (TRM-19 and TRM-20) is not damaged;
• try replacing each of the circuit boards in turn (digital plan board, download and inverter
board) and check whether the communication works.
Page 6.30
erter;
"THE EQUIPMENT IS BLOCKED"
MESSAGE ON THE DISPLAY
Turn the machine of f and on
again. Is the inv erter on?
YES
Is the communication
between the upper and
lower assemblies ok?
RUN EXCITE: Service & Maintenance Manual - rev. 1.5
blies;
NO
Carry out the "Inv erter is
YES
1
NO
of f " troubleshooting
procedure
2
Reinstate the
communication link
between the upper and
lower assemblies