Advertisement

E XCITE, ENGAGING C ARDIO
CLIMB
User manual

Advertisement

Table of Contents
loading

Summary of Contents for Technogym Climb

  • Page 1 E XCITE, ENGAGING C ARDIO CLIMB User manual...
  • Page 2: Table Of Contents

    Levelling ......................16 Electrical connection ..................18 Connection to another device..............20 Routine maintenance ..................22 Extraordinary maintenance ................24 Troubleshooting .....................25 Technical assistance ..................27 Storage ......................28 Disposal ......................29 Switching on and off ..................30 Monitoring the heart rate ................31 Using the equipment ..................34 Climb Excite...
  • Page 3: Important Safety Instruction

    Any other use is to be considered improper and therefore dangerous. Do not use attachments not recommended by Technogym. Never operate the equipment if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. In this case, contact the Technogym Technical Support service.
  • Page 4 To disconnect, turn all controls to the off position, then remove plug from outlet. SAVE THESE INSTRUCTIONS Warnings Do not connect a device with load exceeding 7A. Risk Of Electric Shock. Do Not Disconnect Under Load. Do not connect to a circuit operating at more than 150V to Ground. Climb Excite...
  • Page 5: Personal Safety

    Keep all electrical components, such as the power cable and I/0 switch, away from liquids to prevent shock. Maintain the equipment in good working condition. If there are signs of wear, contact the Technogym Technical Support service. Do not attempt to service the equipment yourself other than the maintenance instructions found in the user manual.
  • Page 6 Do not set anything on the casing or control panel. Technogym is not responsible for any damages due to any failures or damage caused by unauthorized service, misuse, accident, negligence, improper assembly or installation, debris resulting from any construction activities in the product’s environment, rust or corrosion as a result of the product’s location, alterations or modifications without Technogym’s written authorization or for failure on your part to use, operate and maintain the products...
  • Page 7: Manufacturer And Equipment Identification

    Serial number and date of manufacture Product model The Climb is a commercial device, designed for use in residential and professional environments. It is a class SA device, pursuant to ISO EN 20957-1. The precision class was measured at 106 spm, level 12 and step height of 20.6 cm.
  • Page 8: Description Of The Equipment

    Footrests (G): you can take a short rest by moving your feet onto the footrests, in the event of fatigue or danger. Bottle holder (H): for standing the water bottle on during the workout. Reading stand (L): for standing magazines or books on. Climb Excite...
  • Page 9: Technical Data

    0÷999 min ± 1% Distance 0÷9999 floors ± 5% Noise level Less than 70 dB Protection grade IP 20 Operating temperature from +10°C to +35°C Maximum capacity of water bottle-holder 2 kg (4 lb) Electric isolation class Class I Climb Excite...
  • Page 10 Technical data 1300 mm 770 mm (30") (51") 470 mm (19") 1890 mm (74") 265 mm (10") Climb Excite...
  • Page 11: Accessories

    Accessories The equipment’s standard outfit comprises: A Set of wrenches B User manual C Warranty certificate D CEE Power Supply cable with SH socket E Two replacement fuses (2 x 3.15A (F) Climb Excite...
  • Page 12: Safety Devices And Warnings

    E Safety sensors: located on the access side of the product. If the sensors detect a presence in this area, they lock the steps. To restart movement of the steps, press the START button on the control panel. The START button is active only when the sensor zone is not occupied. Climb Excite...
  • Page 13 Please read the adhesive labels on the equipment, which provide information about possible risks and hazards. F The label near the main switch lists the equipment's electrical characteristics. G The label which can be affixed to the power supply cable states the electrical specifications for the cable. Climb Excite...
  • Page 14: Place Of Usage

    The place of installation must comply with all the suitability requirements laid down in current legislation on this matter. In order to guarantee the performance indicated by the manufacturer, you are advised against using the equipment in zones with high short-wave presence or similar. 600 mm (24") Climb Excite...
  • Page 15: Moving The Equipment

    If wheels cannot be used on the floor, move the equipment with normal lifting and transport methods. Warnings Take great care when moving the equipment, as it may overbalance. Do not grip the steps or the control panel when lifting or moving the equipment. Climb Excite...
  • Page 16: Levelling

    Levelling The equipment is levelled by adjusting the two fixed feet. remove the lower guard (B); remove the side guard (C), Climb Excite...
  • Page 17 (E) in or out until the frame is in a stable position; tighten up the lock nut (D) after adjusting; reposition the side guard (C), applying pressure; Reposition the lower guard (B), applying pressure. Climb Excite...
  • Page 18: Electrical Connection

    The wall socket must be located in a place where the plugging and unplugging can be done easily and safely. When plugging in, the switch on the equipment must be in the 0 position (i.e. the equipment must be switched off). Check the state of the power supply cable periodically. Climb Excite...
  • Page 19 Do not modify the plug provided with the product; if it will not fit in the outlet, have a proper outlet installed by a qualified electrician. Climb Excite...
  • Page 20: Connection To Another Device

    IEC 60601-1 for medical electrical equipment). Whoever connects additional equipment to the input or output signal ports, configures a medical system and therefore is responsible for the system’s conformity to the IEC 60601-1 standard about systems. Consult the technical support department or your local representative if you have any doubts. Climb Excite...
  • Page 21 The wall socket of the aerial cable must be positioned so that the plug can be easily inserted and removed. A network socket can be found next to the aerial socket for the Ethernet connection. Climb Excite...
  • Page 22: Routine Maintenance

    Move the step downwards, to the position shown in the illustration. Apply oil to every opening in the hinge. Repeat for each of the 8 steps. Warning Before placing the product back in service, remove any excess lubricant from the surface of the steps with a cloth. Climb Excite...
  • Page 23 Replace defective or worn components immediately, or remove the product from service. The routine maintenance, adjustment and lubrication jobs must be performed by the Technogym Technical Support Service. Before starting any job, turn the equipment off by switching the switch to the 0 position and unplug the power cable from the wall socket.
  • Page 24: Extraordinary Maintenance

    After installation of the Climb product, transmission parts (belts, chains) must be replaced every 3 years. If the buyer fails to replace these components, Technogym will be discharged from any liability for bodily injury or property damage arising out of the malfunction of the product’s transmission unit.
  • Page 25: Troubleshooting

    Contact the Technogym Technical Support Service. Equipment doesn’t switch Installation problems with the power supply cable. Check the connection. To replace the blown fuse with a spare contact Technogym Burnt-out fuses. Technical Support Service. The control panel connector has been accidentally Contact the Technogym Technical Support Service.
  • Page 26 Chest band transmitter not making proper skin contact. Dampen the inside of the chest band with water. Damaged transmitter. Change the chest band. The steps do not remain The brake is disabled. Contact the Technogym Technical Support Service. locked in place The product is The safety sensors are damaged. Contact the Technogym Technical Support Service.
  • Page 27: Technical Assistance

    Via Calcinaro 2861, 47521 Cesena Italy on-site servicing tel: +39 0547 56047 supply of original spare parts. http://www.technogym.com/Support When you contact the Technogym Technical Support Service you must give the following information: model, date of purchase, serial number, precise description of the problem.
  • Page 28: Storage

    If a long period of non-use is expected, you are advised to store the equipment in the following way: in a clean dry place, with a dust cover; at a room temperature between -10°C and 70°C and relative humidity between 20% and 90%. For better storage, use the original packing materials. Climb Excite...
  • Page 29: Disposal

    Following measures implemented by the member states of the European Union, private citizens resident in the EC can take their used electrical and electronic equipment to authorised collection centres for disposal. If the product is used commercially, contact your reseller or Technogym Customer Service in your country to arrange collection and disposal of the electrical or electronic waste.
  • Page 30: Switching On And Off

    Warning The switch is for turning the equipment on and off but does not isolate it completely from the mains voltage, even in the “0” position (off). For complete isolation you must unplug the power supply plug. Climb Excite...
  • Page 31: Monitoring The Heart Rate

    80 cm. Heart rate readings will not be accurate near electromagnetic radiation sources (TVs, cellphones, etc.). Should you have any doubts about the accuracy of the readings, contact the Technical Support Service. Climb Excite...
  • Page 32 Combined use of fats and sugars Significant improvement of aerobic efficiency. Prevalent use of fats and increased use of sugars Moderate improvement of aerobic efficiency. Prevalent use of fats, and modest use of sugars Limited improvement of aerobic efficiency. Climb Excite...
  • Page 33 The heart rate shown on the display is purely indicative and cannot be considered absolutely certain. You are advised not to use a chest band with heart rate monitor if you have a cardiac support device such as a pacemaker or similar. Climb Excite...
  • Page 34: Using The Equipment

    Using the equipment Climb up onto the equipment from the rear, using the step provided (A). Grasp one of the handgrips with one hand, and use the other to set a program on the control panel. The steps will remain locked until the START button is pressed.
  • Page 35 To get off the device in an emergency, grasp the side handgrips, support your weight on them and move your feet onto the footrests. Then get off the equipment. Climb is designed solely for the use it was designed and manufactured for, as a stair simulator. Any other use of the equipment is to be considered improper and therefore dangerous.
  • Page 36 Climb_Excite_en-AB 0SM00977...

Table of Contents