Technogym Run Excite 500 Service Maintenance Manual page 89

Up to 25km/h speed
Hide thumbs Also See for Run Excite 500:
Table of Contents

Advertisement

RUN EXCITE: Service & Maintenance Manual - rev. 1.5
(12) Place the tester probes across the
The measured voltage should be approxim
pin 5 and pin 4 of the connector CN5 of the CPU board. The measured voltage shoul
approximately 12 Vdc. Place the tester probes across the live pin 3 and pin 2 of the connector
CN5 of the CPU board. The measured voltage should be approximately 3.3 Vdc.
(13) As for step (12) but on connector CN1 of the LCD inverter board.
(14) Place the tester probes across the 2 pins of the CN2, CN3, CN4 and CN5 connectors. The
measured voltage should be approximately 300 VAC.
To do this correctly, it is recommended to turn off the machine, position the
probes. and then turn it back on.
WARNING: high voltages are present on these connectors.
live pin 1 and pin 2 of the connector CN5 of the CPU board.
ately 12 Vdc. Place the tester probes across the live
d be
Page 6.21