Feature
Voltage input
Input resistance
Sampling frequency
Accuracy
Electric strength of external voltage
A/D converter
Current input, parameterisable
Input resistance
Input current in case of open circuit
Sampling frequency
Accuracy
Electric strength of external voltage
A/D converter
24 V supply of the external sensors or
potential−free contacts
Total current for X4x, X50/X8x
Feature
Pos. clock signal
Neg. clock signal
Pos. data line
Neg. data line
Not assigned
Not assigned
24 V supply of the external SSI encoders
Total current for X4x, X50/X8x
Features
Reach
Angle of incidence
l
Rated value
0.3 ... 10 V
¢
(V < 0.3 V
"0")
> 80 kW
1 kHz (1 ms)
± 0.1 V
± 15 V
Resolution 10 bits + sign
Error: 1 digit º 0.1 %, based on the final value
¢
0.6 ... +20 mA (I < 0.6mA
"0")
4 ... +20 mA, fail−safe
220 W
Display "0" (I < 0.6 mA)
1 kHz (1 ms)
± 0.2 mA
± 15 V
10 bit resolution
Error: 1 digit º 0.1 %, based on the final value
External supply at 24E: Voltage drop < 2.5 V
1 A
Rated value
Bit rate: 100 .... 1000 kbits
Data word width: 1 ... 32 bits (effective)
Code: Gray an binary
External supply at 24E: Voltage drop < 2.5 V
1 A
Rated value
~5 m