Control Terminals; Digital Inputs - Lenze 8400 protec Hardware Manual

L-force drives
Table of Contents

Advertisement

4
Technical data

Control terminals

Digital inputs

4.7
Control terminals
4.7.1
Digital inputs
X41 ... X43
Pin / Name
4 / DI1
2 / DI2
4 / DI3
2 / DI4
4 / DI5
2 / DI6
1 / 24O
3 / GIO
Extensions in the EMS version
X45 ... X48
Pin / Name
4 / DI7
2 / DI8
4 / DI9
2 / DI10
4 / DI11
2 / DI12
4 / DI13
2 / DI14
5 / n. c.
1 / 24O
3 / GIO
64
Features
Digital input 1/2 at X41
Digital input 3/4 at X42
Digital input 5/6 at X43
24 V supply of the external sensors or
potential−free contacts
Total current for X4x, X50/X8x
Features
Digital input 7/8 at X45
Digital input 9/10 at X46
(configurable with DO3/DO4)
Digital input 11/12 at X47
Digital input 13/14 at X48
not assigned
24 V supply of the external sensors or
potential−free contacts
Total current for X41 ... X48
l
Rated value
according to IEC 61131−2, type 1
or
two−track frequency input for HTL encoder
0 ... 100 kHz
according to IEC 61131−2, type 1
DI4 − typical delay time:
5 ms at rising edge
l
25 ms at falling edge
l
according to IEC 61131−2, type 1
or
Single−channel frequency input, 0 ... 10 kHz
DI5/DI6 − typical delay time:m
5 ms at rising edge
l
25 ms at falling edge
l
External supply at 24E: Voltage drop < 2.5 V
1 A
Rated value
according to IEC 61131−2, type 1
External supply at 24E: Voltage drop < 2.5 V
1 A
EDS84DPS424 EN 5.0

Advertisement

Table of Contents
loading

Table of Contents