Safety engineering

Overview of safety options

11.3
Overview of safety options
Depending on the device version, the following safety functions are available:
Safety option 10
Due to safety option 10, the following safety functions can be used:
Safe torque off (STO),
ƒ
formerly: safe standstill
If requested, the safe disconnection of the drive is achieved through:
Directly connected active sensors
ƒ
Passive sensors connected to a safety switching device
ƒ
The safety functions are suitable for applications according to IEC 61508 to SIL 3 and
achieve a performance level (PL) e and the control category 4 according to EN ISO 13849−1.
Safety option 20
Due to safety option 20, the following safety functions can be used:
Safe torque off (STO),
ƒ
formerly: safe standstill
Safe stop 1 (SS1)
ƒ
Safe stop emergency (SSE)
ƒ
Safe operation mode selector (OMS)
ƒ
Safe enable switch (ES)
ƒ
The safe disconnection of the drive is achieved through:
a higher−level safety PLC via PROFIsafe/PROFINET
ƒ
a higher−level safety PLC via PROFIsafe/PROFIBUS
ƒ
The functions of the safety option must be parameterised via the »Engineer«.
The motion functions are continued to be executed by the controller. The drive−based
safety monitors the safe compliance with the limit values. When the limit values are
exceeded, the drive−based safety starts the control functions according to EN 60204−1
directly in the controller.
The safety functions are suitable for applications according to IEC 61508 to SIL 3 and
achieve a performance level (PL) e and the control category 3 according to EN ISO 13849−1.