Wiring - Lenze 8400 protec Hardware Manual

L-force drives
Table of Contents

Advertisement

Installation according to EMC (installation of a CE−typical drive system)
7.4.4

Wiring

Notes on the laying of cables:
In the case of greater cable lengths, a greater cable distance between the cables is
ƒ
required.
In the case of parallel routing (cable trays) of cables with different types of signals,
ƒ
the degree of interference can be minimised by using a metallic cable separator or
isolated cable ducts.
Cover
Signal cables
Fig. 7−3
Cover
Cable duct
Fig. 7−4
EDS84DPS424 EN 5.0
Electrical installation − EMS version
Barrier without
opening
Power cables
Cable routing in the cable duct with barrier
Communication cables
Measuring cables
Analog cables
Control cables
Power cables
Cable routing in separated cable ducts
l
7
Wiring
EMVallg001
EMVallg002
115