Siemens SINAMICS G120C Getting Started page 57

Low-voltage converters. built-in devices, frame size a...c
Hide thumbs Also See for SINAMICS G120C:
Table of Contents

Advertisement

p8924
PN DHCP mode
p8925
PN interfaces configuration
0:
No function
1:
Activate the configuration
2:
Activate the configuration and save
3:
Delete configuration
p8929
PN Remote Controller number
0:
Automation or Safety
1:
Automation and Safety
r8930
PN Name of Station active
r8931
PN IP Address of Station active
r8932
PN Default Gateway of Station active
r8933
PN Subnet Mask of Station active
r8934
PN DHCP mode active
r8935
PN MAC Address of Station
r8939
PN DAP ID
r8960
PN Subslot assignment
r8961
PN IP Addr Remote Controller 1
r8962
PN IP Addr Remote Controller 2
p8980
Ethernet/IP profile
0:
SINAMICS
p8981
Ethernet/IP ODVA STOP mode
0:
OFF1
p8982
Ethernet/IP ODVA speed (p8982) or torque
(p8983) scaling
p8983
123:
32
125:
8
127:
2
129:
0,5
131:
0,125
133:
0,03128
p8991
USB memory access
p9400
Safely remove memory card
0
No memory card inserted
1
Memory card inserted
2
Request "safe removal" of the memory
card
3
"Safe removal" possible
100
"Safe removal" not possible due to access
r9401
Safely remove memory card status
r9463
Set valid macro
p9484
BICO interconnections, search signal source
SINAMICS G120C converter
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
1:
ODVA / AC/DC
1:
OFF2
124:
16
126:
4
128:
1
130:
0,25
132:
0,0625
4.2 Commissioning with BOP-2 operator panel
r9485
BICO interconnections, search signal source
number
r9486
BICO interconnections, search signal source first
index
p9601
SI enable, functions integrated in the drive
(processor 1)
p9610
SI PROFIsafe address (processor 1)
p9650
SI F-DI changeover, tolerance time (processor 1)
[ms]
p9651
SI STO debounce time (processor 1) [ms]
p9659
SI forced checking procedure timer [h]
r9660
SI forced checking procedure remaining time [h]
r9670
SI module identifier, Control Unit
r9672
SI module identifier, Power Module
p9700
SI copy function
p9701
Acknowledge SI data change
p9761
SI password input [hex]
p9762
SI password new [hex]
p9763
SI password acknowledgment [hex]
r9768
SI PROFIsafe control words received (processor
1)
[0] PZD 1
r9769
SI PROFIsafe status words send (processor 1)
[0] PZD 1
r9770
SI version, safety functions integrated in the drive
(processor 1)
r9771
SI common functions (processor 1)
r9772
CO/BO: SI status (processor 1)
r9773
CO/BO: SI status (processor 1 + processor 2)
r9776
SI diagnostics
.00
1 = safety parameters changed, POWER
ON required
.01
1 = safety functions enabled
.02
1 = safety components exchanged and
save necessary
r9780
SI monitoring clock cycle (processor 1) [ms]
r9781
SI checksum to check changes (processor 1)
r9782
SI time stamp to check changes (processor 1) [h]
r9794
SI crosswise comparison list (processor 1)
r9795
SI diagnostics, STOP F (processor 1)
r9798
SI actual checksum SI parameters (processor 1)
p9799
SI reference checksum SI parameters (processor
1)
Commissioning
...
[7]
PZD 8
...
[7]
PZD 8
57

Advertisement

Table of Contents
loading

Table of Contents