r2138
CO/BO: Control word, faults/alarms
r2139
CO/BO: Status word, faults/alarms 1
p2141
Speed threshold value 1 [rpm]
p2153
Speed actual value filter time constant [ms]
p2156
Switch-on delay comparison value reached [ms]
r2169
CO: Speed actual value smoothed signals [rpm]
p2170
Current threshold value [A]
p2171
Current threshold value reached delay time [ms]
p2174
Torque threshold value 1 [Nm]
p2194
Torque threshold value 2 [%]
p2195
Torque utilization switch-off delay [ms]
r2197
CO/BO: Status word monitoring functions 1
r2198
CO/BO: Status word monitoring 2
r2199
CO/BO: Status word monitoring 3
p2200
BI: Technology controller enable
p2201
CO: Techn. controller fixed value 1 [100 ≙ 100%]
p2202
CO: Techn. controller fixed value 2 [100 ≙ 100%]
p2203
CO: Techn. controller fixed value 3 [100 ≙ 100%]
p2204
CO: Techn. controller fixed value 4 [100 ≙ 100%]
p2205
CO: Techn. controller fixed value 5 [100 ≙ 100%]
p2206
CO: Techn. controller fixed value 6 [100 ≙ 100%]
p2207
CO: Techn. controller fixed value 7 [100 ≙ 100%]
p2208
CO: Techn. controller fixed value 8 [100 ≙ 100%]
p2209
CO: Techn. controller fixed value 9 [100 ≙ 100%]
p2210
CO: Techn. controller fixed value 10 [100 ≙ 100%]
p2211
CO: Techn. controller fixed value 11 [100 ≙ 100%]
p2212
CO: Techn. controller fixed value 12 [100 ≙ 100%]
p2213
CO: Techn. controller fixed value 13 [100 ≙ 100%]
p2214
CO: Techn. controller fixed value 14 [100 ≙ 100%]
p2215
CO: Techn. controller fixed value 15 [100 ≙ 100%]
p2216
Techn. controller fixed value selection method
0
Fixed value selection direct
1
Fixed value selection binary
p2220
BI: Techn. controller fixed value selection bit 0
p2221
BI: Techn. controller fixed value selection bit 1
p2222
BI: Techn. controller fixed value selection bit 2
p2223
BI: Techn. controller fixed value selection bit 3
r2224
CO: Techn. controller fixed value active [100 ≙
100%]
r2225
CO/BO: Techn. controller fixed value selection
status word
r2229
Techn. controller number currently
SINAMICS G120C converter
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
4.2 Commissioning with BOP-2 operator panel
p2230
Techn. controller motorized potentiometer
configuration
.00
Storage active
.02
Initial rounding active
.03
Non-volatile data save active for
p2230.0 = 1
.04
Ramp-function generator always active
r2231
Techn. controller motorized potentiometer setpoint
memory
p2235
BI: Techn. controller motorized potentiometer
setpoint up
p2236
BI: Techn. controller motorized potentiometer
setpoint down
p2237
Techn. controller motorized potentiometer
maximum value [%]
p2238
Techn. controller motorized potentiometer
minimum value [%]
p2240
Techn. controller motorized potentiometer start
value [%]
r2245
CO: Techn. controller motorized potentiometer
setpoint before RFG [100 ≙ 100%]
p2247
Techn. controller motorized potentiometer ramp-
up time [s]
p2248
Techn. controller motorized potentiometer ramp-
down time [s]
r2250
CO: Techn. controller motorized potentiometer
setpoint after RFG [100 ≙ 100%]
p2251
Techn. controller mode
0
Techn. controller as main speed setpoint
1
Techn. controller as additional speed setpoint
p2253
CI: Techn. controller setpoint 1 [100 ≙ 100%]
p2254
CI: Techn. controller setpoint 2 [100 ≙ 100%]
p2255
Techn. controller setpoint 1 scaling [100 ≙ 100%]
p2256
Techn. controller setpoint 2 scaling [100 ≙ 100%]
p2257
Techn. controller ramp-up time [s]
p2258
Techn. controller ramp-down time [s]
r2260
CO: Techn. controller setpoint after ramp function
generator [100 ≙ 100%]
p2261
Techn. controller setpoint filter time constant [s]
p2263
Techn. controller type
0
D component in the actual value signal
1
D component in the fault signal
p2264
CI: Techn. controller actual value [100 ≙ 100%]
p2265
Techn. controller actual value filter time constant
[s]
r2266
CO: Techn. controller actual value after filter [100
≙ 100%]
Commissioning
53