p1000
Speed setpoint selection
p1001
CO: Fixed speed setpoint 1 [rpm]
p1002
CO: Fixed speed setpoint 2 [rpm]
p1003
CO: Fixed speed setpoint 3 [rpm]
p1004
CO: Fixed speed setpoint 4 [rpm]
p1005
CO: Fixed speed setpoint 5 [rpm]
p1006
CO: Fixed speed setpoint 6 [rpm]
p1007
CO: Fixed speed setpoint 7 [rpm]
p1008
CO: Fixed speed setpoint 8 [rpm]
p1009
CO: Fixed speed setpoint 9 [rpm]
p1010
CO: Fixed speed setpoint 10 [rpm]
p1011
CO: Fixed speed setpoint 11 [rpm]
p1012
CO: Fixed speed setpoint 12 [rpm]
p1013
CO: Fixed speed setpoint 13 [rpm]
p1014
CO: Fixed speed setpoint 14 [rpm]
p1015
CO: Fixed speed setpoint 15 [rpm]
p1016
Fixed speed setpoint mode
1
Direct selection
2
Selection, binary coded
p1020
BI: Fixed speed setpoint selection bit 0
p1021
BI: Fixed speed setpoint selection bit 1
p1022
BI: Fixed speed setpoint selection bit 2
p1023
BI: Fixed speed setpoint selection bit 3
r1024
CO: Fixed speed setpoint effective [100 % ≙
p2000]
r1025
BO: Fixed speed setpoint status
p1030
Motorized potentiometer configuration
00
Storage active
01
Automatic operation, ramp-function
generator active
02
Initial rounding active
03
Storage in NVRAM active
p1035
BI: Motorized potentiometer setpoint raise
p1036
BI: Motorized potentiometer setpoint lower
p1037
Motorized potentiometer maximum speed [rpm]
p1038
Motorized potentiometer minimum speed [rpm]
p1040
Motorized potentiometer start value [rpm]
p1043
BI: Motorized potentiometer, accept setting value
p1044
CI: Motorized potentiometer setting value [100 %
≙ p2000]
r1045
CO: Motorized potentiometer, setpoint in front of
the ramp-function generator [rpm]
SINAMICS G120C converter
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
4.2 Commissioning with BOP-2 operator panel
p1047
Motorized potentiometer ramp-up time [s]
p1048
Motorized potentiometer ramp-down time [s]
r1050
CO: Motorized potentiometer setpoint after the
ramp-function generator [100 % ≙ p2000]
p1055
BI: Jog bit 0
p1056
BI: Jog bit 1
p1058
Jog 1 speed setpoint [rpm]
p1059
Jog 2 speed setpoint [rpm]
p1070
CI: Main setpoint [100 % ≙ p2000]
p1071
CI: Main setpoint scaling [100 ≙ 100%]
r1073
CO: Main setpoint effective [100 % ≙ p2000]
p1075
CI: Supplementary setpoint [100 % ≙ p2000]
p1076
CI: Supplementary setpoint scaling [100 ≙ 100%]
r1077
CO: Supplementary setpoint effective
[100 % ≙ p2000]
r1078
CO: Total setpoint effective [100 % ≙ p2000]
p1080
Minimum speed [rpm]
p1081
Maximum speed scaling [%]
p1082
Maximum speed [rpm]
p1083
CO:Speed limit in positive direction of rotation
[rpm]
r1084
CO: Speed limit positive effective [100 % ≙ p2000]
p1086
CO: Speed limit in negative direction of rotation
[rpm]
r1087
CO: Speed limit negative effective [100 % ≙
p2000]
p1091
Skip speed 1 [rpm]
p1092
Skip speed 2 [rpm]
p1101
Skip speed bandwidth [rpm]
p1106
CI: Minimum speed signal source
p1110
BI: Inhibit negative direction
p1111
BI: Inhibit positive direction
p1113
BI: Setpoint inversion
r1114
CO: Setpoint after the direction limiting [100 % ≙
p2000]
r1119
CO: Ramp-function generator setpoint at the input
[100 % ≙ p2000]
p1120
Ramp-function generator ramp-up time [s]