Siemens SINAMICS G120C Getting Started page 48

Low-voltage converters. built-in devices, frame size a...c
Hide thumbs Also See for SINAMICS G120C:
Table of Contents

Advertisement

Commissioning
4.2 Commissioning with BOP-2 operator panel
p1121
Ramp-function generator ramp-down time [s]
p1130
Ramp-function generator initial rounding-off time
[s]
p1131
Ramp-function generator final rounding-off time
[s]
p1134
Ramp-function generator rounding-off type
0
Continuous smoothing
1
Discontinuous smoothing
p1135
OFF3 ramp-down time [s]
p1136
OFF3 initial rounding-off time [s]
p1137
OFF3 final rounding-off time [s]
p1138
CI: Acceleration ramp scaling [100 ≙ 100%]
p1139
CI: Ramp down scaling [100 ≙ 100%]
p1140
BI: Enable ramp-function generator
p1141
BI: Continue ramp-function generator
p1142
BI: Enable speed setpoint
r1149
CO: Ramp-function generator acceleration [100 %
≙ p2007]
r1170
CO: Speed controller setpoint sum
[100 % ≙ p2000]
r1198
CO/BO: Control word, setpoint channel
p1200
Flying restart operating mode
0
Flying restart inactive
1
Flying restart always active (start in setpoint
direction)
4
Flying restart always active (start only in
setpoint direction)
p1201
BI: Flying restart enable signal source
p1202
Flying restart search current [100 % ≙ r0331]
p1203
Flying restart search rate factor [%]
A higher value results in a longer search time.
p1206
Set fault number without automatic restart
p1210
Automatic restart mode
0
Inhibit automatic restart
1
Acknowledge all faults without restarting
4
Restart after line supply failure, without
additional start attempts
6
Restart after fault with additional start
attempts
14 Restart after line supply failure following
manual acknowledgement
16 Restart after fault following manual
acknowledgement
48
26 Acknowledging all faults and restarting for an
ON command
p1211
Automatic restart, start attempts
p1212
Automatic restart, delay time start attempts [s]
p1213
Automatic restart, monitoring time [s]
[0] Restart
p1215
Motor holding brake configuration
0
No motor holding brake being used
3
Motor holding brake like sequential control,
connection via BICO
p1216
Motor holding brake, opening time [ms]
p1217
Motor holding brake, closing time [ms]
p1230
BI: DC braking activation
p1231
DC braking configuration
0
No function
4
DC braking
5
DC braking OFF1/OFF3
14 DC braking below starting speed
p1232
DC braking, braking current [A]
p1233
DC braking time [s]
p1234
Speed at the start of DC braking [rpm]
r1239
CO/BO: DC braking status word
p1240
V
controller or V
DC
(vector control)
0
Inhibit V
controller
DC
1
Enable V
DC_max
2
Enable V
DC_min
3
Enable V
DC_min
controller
r1242
V
controller switch-in level [100 % ≙ p2001]
DC_max
p1243
V
controller dynamic factor [%]
DC_max
p1245
V
controller switch-in level (kinetic buffering)
DC_min
[%]
r1246
V
controller switch-in level (kinetic buffering)
DC_min
[100 % ≙ p2001]
p1247
V
controller dynamic factor (kinetic buffering)
DC_min
[%]
p1249
V
controller speed threshold [rpm]
DC_max
p1254
V
controller automatic ON level detection
DC_max
0
Automatic detection inhibited
1
Automatic detection enabled
p1255
V
controller time threshold [s]
DC_min
p1256
V
controller response (kinetic buffering)
DC_min
0
Buffer V
until undervoltage, n<p1257 →
DC
F07405
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
[1]
Reset start counter
monitoring configuration
DC
controller
controller (kinetic buffering)
controller and V
DC_max
SINAMICS G120C converter