Interface assignment
Table 3- 10
Representation
For Pin 1 / Pin 8: The associated temperature channel (T1) can be assigned parameters as an
For Pin 6 / Pin 9: At an encoder supply of 5 V, the voltage drops on the encoder supply cables are
NOTICE
The KTY temperature sensor must be connected with the correct polarity. A sensor
connected with the incorrect polarity cannot detect the motor overheating. For more
information on the temperature sensors and how to use them, refer to the
Commissioning Manual, chapter entitled Temperature sensors for SINAMICS components.
Note
There are two ways of connecting the temperature sensor:
1. Via X120, terminal 1 and 2
2. Via X23, pin 1 and 8
SIMOTION D410-2
Manual, 02/2012
Interface assignment X23
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
individual channel or together in combination with the second temperature channel (T2) at
interface X120.
(For parameterization, refer to the
recorded and compensated by means of the sense cables. For this purpose, the sensor supply is
corrected on the SIMOTION D410-2.
3.4 Encoder interface (HTL/TTL/SSI)
Name
+Temp
SSI_CLK
SSI_XCLK
P_Encoder 5 V / 24 V
P_Encoder 5 V / 24 V
P_Sense
G_Encoder (G)
-Temp (G)
G_Sense (G)
RP
RN
BN
BP
AN_SSI_XDAT
AP_SSI_DAT
SINAMICS S120
Commissioning Manual).
Description
KTY or PTC input
SSI clock positive
SSI clock negative
Encoder power supply
Encoder power supply
Sense input encoder power supply
Ground for sensor power supply
Ground for KTY or PTC
Ground sense input
R track positive
R track negative
B track negative
B track positive
A track negative / SSI data negative
A track positive / SSI data positive
SINAMICS S120
Interfaces