SFC
SFC Name
No.
14
GET
Read data from remote CPU
(one area specified)
JOB activated
JOB checked
JOB finished (NDR = 1; 1 - 450 bytes)
15
PUT
Write data to remote CPU
JOB activated (1 - 404 bytes)
JOB checked
JOB finished (DONE = 1)
16
PRINT
Send data to a printer
JOB activated, REQ = 1
JOB checked
JOB finished, DONE = 1
S7-400 Instruction List
A5E00267845-01
Function
335
149
282 -
316
445 -
478
149
147
462 -
502
153
152
Execution Time in ms
CPU
CPU
CPU
412
414
416
186
129
86
57
163 -
108 -
183
121
257 -
173 -
277
180
86
57
85
56
260 -
174 -
284
186
88
58
86
57
System Function Blocks
CPU
CPUs
CPUs
417
414-4H
414-4H
417-4H
417-4H
(solo)
(redun-
dant)
113
xx
xx
49
xx
xx
92 - 106
xx - xx
xx - xx
147 -
xx - xx
xx - xx
160
49
xx
xx
48
xx
xx
150 -
xx - xx
xx - xx
162
50
xx
xx
49
xx
xx
141