Siemens CPU 412-1 Instruction Manual Page 25

S7-400; cpu 412 series; cpu 414 series; cpu 416 series; cpu 417 series;.
Hide thumbs

Advertisement

Execution Time for Addressing Via Parameters
Example
A Parameter ... with I 0.5 in the block parameter list with CPU 414
Step 1:
Load input I 0.5 addressed via the parameter (the time required is in the table on page 20)
Address is in ...
Parameter (double word)
Step 2:
AND link of the input addressed this way (see page 25 for the execution time)
Total execution time
0.24 ms
0.075 ms
+
0.315 ms
S7-400 Instruction List
A5E00267845-01
:
:
:
Typical Execution Time in ms
Direct Addressing
0.06/0.075
:
Examples of Calculations
Execution Time in ms
:
0.24
Indirect Addressing
0.075+
Time for A I
:
23