Load Instructions, continued
In-
In-
Address
Address
struc-
struc-
ID
tion
L
Load ...
k8
8-bit constant into ACCU1-LL
k16
16-bit constant into ACCU1-L
k32
32-bit constant into ACCU1
Parameter
Load constant into ACCU1
(addressed via parameter)
L
2#n
Load 16-bit binary constant into
ACCU1-L
Load 32-bit binary constant into
ACCU1
B#16#p
Load 8-bit-hexadecimal constant
into ACCU1-L
L
W#16#p
Load 16-bit hexadecimal
constant into ACCU1-L
DW#16#p
Load 32-bit hexadecimal
constant into ACCU1
S7-400 Instruction List
A5E00267845-01
Length
Length
in
in
Description
Description
Words
2
2
3
2
2
3
1
2
3
Execution Time in ms
Execution Time in ms
CPU 412
CPU 414
0.125
0.075
0.125
0.075
0.185
0.112
0.3+
0.18+
0.125
0.075
0.185
0.112
0.1
0.06
0.125
0.075
0.185
0.112
Load Instructions
CPU 416
CPU 417
0.05
0.042
0.05
0.042
0.075
0.062
0.12+
0.12+
0.05
0.042
0.075
0.062
0.04
0.03
0.05
0.042
0.075
0.065
50