Siemens CPU 412-1 Instruction Manual page 126

S7-400; cpu 412 series; cpu 414 series; cpu 416 series; cpu 417 series;
Hide thumbs Also See for CPU 412-1:
Table of Contents

Advertisement

SFC
SFC Name
No.
51
RDSYSST
Central
Display the diagnostic status of the
expansion devices (0692)
51
RDSYSST
Distributed
Display the diagnostic status of the DP
system 1 stations (via integrated DP
interface) (0692)
51
RDSYSST
Diagnostic status of the stations of a DP
master system connected via an external
DP interface (4692)
First call
Intermediate call
Last call
51
RDSYSST
"Advanced DP master system information"
partial list
Display advanced information via a DP
master system (0195)
Display header information (0F95)
S7-400 Instruction List
A5E00267845-01
Function
Execution Time in ms
CPU
CPU
CPU
412
414
416
280
168
111
811
487
323
252
148
97
140
84
55
157
94
62
156
93
61
114
69
45
System Functions
CPU
CPU
CPU
417
414-4H
414-4H
417-4H
417-4H
(solo)
(redun-
dant)
96
xx
xx
273
xx
xx
87
xx
xx
49
--
--
55
--
--
55
xx
xx
40
xx
xx - xx
124

Hide quick links: