Parameterization
Parameter
Submenu
Unit
Unit Qm
kg/min
Unit Qv
l/min
Density unit
kg/l
Unit totalizer
kg
Unit totalizer
l
Submenu
Prog. Unit Qm
66
Value range / input type
g/s, g/min, g/h,
kg/s, kg/min, kg/h,
kg/d, t/min, t/h,
t/d, lb/s, lb/min,
lb/h, lb/d, abc/s,
abc/min, abc/h,
abc/d
l/s, l/min, l/h,
m
m
ft
ugl/s, ugl/min,
ugl/h, mgl/d, igps,
igpm, igph, igpd,
bbl/s, bbl/min,
bbl/h, bbl/d, abc/s,
abc/min, abc/h,
abc/d
g/ml, g/l, g/cm
kg/l, kg/m
lb/ugl
g, kg, t, lb, abc
l, m
bbl, abc
Unit name
3 ASCII
abc
Technician*
CoriolisMaster FCM2000
Table
3
3
/s, m
/min,
3
/h, m
3
/d, ft
3
/s,
3
/min, ft
3
/h, ft
3
/d,
3
,
Table
3
3
, lb/ft
,
Table
3
3
, ft
, ugl, igl,
ASCII
Note
In this submenu the units can be defined for the
measured variables (mass flowrate, density and
temperature) and for the calculated variables
(volume flowrate and mass or volume flow totals).
All other flow related entries (e.g., alarm limits or
flow ranges) are then made for those parameters
in the selected units.
This selection defines the units for the mass flow
to be used for the display of both parameters
QmMax and QmMax Meter Pipe and the
instantaneous mass flowrate.
This selection defines the units for the volume
flow to be used for the display of the
instantaneous volume flowrate or for the entries of
the Min- and Max-limits for the current output
when the volume flowrate is to be indicated by the
current output.
The following units can be selected:
In this menu the units for the mass flow totalizer
are defined. Because this menu is restricted to
mass flow only the mass flow unit selections are
displayed.
In this menu the units for the volume flow totalizer
are defined. Because this menu is restricted to
volume flow only the volume flow unit selections
are displayed.
Any user preferred mass flow unit can be defined
in the menus of this submenu. The defined
programmable mass flow unit can be utilized for
the other flow parameters (e.g., totalizer units).
Not contained in the fieldbus software versions.
In this menu the name or abbreviation of the
programmable mass flow unit can be entered. The
name can have a maximum of 3 characters.
Not contained in the fieldbus software versions.