ABB CoriolisMaster FCM2000 Operating Instructions Manual page 11

Mass flowmeter
Hide thumbs Also See for CoriolisMaster FCM2000:
Table of Contents

Advertisement

Converter with ATEX Approval
Fig. 2
1 ATEX approval
2 ATEX temperature classes
3 Order number
4 Complete model number
5 Supply voltage and maximum power
Converter with FM Approval
Fig. 3
1 FM approvals
2 Order number
3 Complete model number
4 Meter size
5 Type of protection
6 Ambient temperature
Pos: 5.20 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @
D184B111U02
FCM2000 MC27
TÜV 99 ATEX1443 X
II 2D T115°C...Tmed
X
II 2G EEx emd [ib] IIC T6
Tmed = 150°C at Tamb = 40°C
Tmed = 140°C at Tamb = 50°C
Tmed = 80°C at Tamb = 60°C
Electrical data, ignition class of output circuits and
temperature classes, see EC-Type Examination Certificate.
Order no.:
000349252 / X004
Model no.:
MC27B11H65F11CE_AB0K
~
U/f nom:
24 V AC/DC
Smax: <12 VA
Size:
"H" (DN 50) / IP 67
Tamb:
-20°C...+60°C
Fitting:
DN 65 / PN 40
C:
Material:
1.4571
72.753
Cal.:
F: +/-0.15% D: +/- 5 g/l
Qmax DN:
920 kg/min
TAG no.: FT–402
ABB Automation Products GmbH
37070 Göttingen – Germany
6 Meter size and protection class
7 Ambient temperature
8 Process connections and pressure rating
9 Meter pipe material and calibration factor
10 Calibration accuracy
11 Maximum flowrate and TAG number
FCM2000 MC27C
XP-IS:
Class I, Div 1, Groups B, C, D;
DIP:
Class II, II, Div 1, Groups E, F, G;
NI:
Class I, II, Div 2, Groups A, B, C, D, F, G
Class II, Div 1, 2
FM
Class I, Zone 1, Group IIB,
Class I, Zone 2, Group IIB
APPROVED
Order no.:
000342641 / X002
Model no.:
MC27C11H50P11IE_AB1G
Size:
"H" (DN 50)
Type:
4X,
IP 67
Tamb:
-20°C...+60°C
U/fnom:
100...230 V~/50...60 Hz Smax: < 25 VA
seal all condults within 18 inches
Fitting:
DN 50 / 150 lb
Mat.:
1.4571
C: 91.003
Cal.:
F/R: +/-0.15%
D: +/- 5 g/l
QmaxDN:
920 kg/min
TAG no.: PX-136
ABB Automation Products GmbH
37070 Göttingen – Germany
7 Supply voltage and
8 Process connections and pressure rating
9 Meter pipe material and calibration factor
10 Calibration accuracy
11 Maximum flowrate and TAG number
CoriolisMaster FCM2000
1
0032
2
IP 67
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
11
max. power
Safety
G00353
G00354
11

Advertisement

Table of Contents
loading

Table of Contents