2 — INSTALLATION & WIRING:
22
Switches, etc.
Circuitry Protection Devices
To protect the control circuitry from accidental shorts, a low current fuse (ap-
propriate for the maximum current draw) should be connected in series with
the battery feed to the keyswitch. Additionally, a high current fuse should be
wired in series with the main contactor to protect the motor, controller, and
batteries from accidental shorts in the power system. The appropriate fuse for
each application should be selected with the help of a reputable fuse manu-
facturer or dealer. The standard wiring diagram (Figure 3, page 8) shows the
recommended location for each fuse.
Mode Select Switch Operation
The two mode select switches (Mode Select 1 and Mode Select 2) together
define the four operating modes. The switch combinations are shown in Table 2.
Wiring for the mode select switches is shown in the standard wiring diagram
(Figure 3, page 8).
OPERATING MODE
MultiMode™ 1
MultiMode™ 2
MultiMode™ 3
MultiMode™ 4

Table 2 MODE SELECTION

MODE
SELECT
SWITCH 1
OPEN
CLOSED
OPEN
CLOSED
MODE
SELECT
SWITCH 2
OPEN
OPEN
CLOSED
CLOSED
Curtis 1244 Manual,
Rev. E