Curtis 1244 User Manual page 96

Multimode electronic motor controller
Table of Contents

Advertisement

APPENDIX C: SPECIFICATIONS
APPENDIX A: GLOSSARY
Nominal input voltage
PWM operating frequency
Electrical isolation to heatsink
KSI input voltage (minimum)
KSI input current (no contactors engaged)
Logic input voltage
Logic input current
Operating ambient temperature range
Heatsink overtemperature cutback
Heatsink undertemperature cutback
Package environmental rating
Weight
Dimensions (L×W×H)
MoDel
NuMBer
1244-44XX
1244-45XX
1244-46XX
1244-47XX
1244-54XX
1244-55XX
1244-56XX
1244-64XX
1244-65XX
1244-66XX
* at 25°C ambient temperature
† 1-minute rating
C-1
A-14
APPENDIX C
SPECIFICATIONS
Table C-1 SPECIFICATIONS: 1244 CONTROLLER
24 –36 V, 36–48 V, and 48–80V
16 kHz
500 V ac (minimum)
16.8 V for 24–36 V systems
160 mA without programmer; 200 mA with programmer
>7.5 V High; <1 V Low
10 mA
-40°C to 50°C (-40°F to 122°F)
85°C (185°F)
-25°C (-13°F)
IP64 / IP67
3.9 kg (8.5 lb)
229 × 178 × 81 mm (9.0" × 7.0" × 3.2")
NoMINal
arMature
Battery
curreNt
voltaGe
lIMIt
(volts)
(amps)
24–36
400
24–36
500
24–36
600
24–36
700
36–48
400
36–48
500
36–48
600
48–80
400
48–80
500
48–80
600
arMature
arMature
2 MIN
1 Hour
ratING
ratING
(amps)
(amps)
400
160
500
175
600
190
700 †
190
400
140
500
160
600
160
400
125
500
140
600 †
140
fIelD
2 MIN
*
ratING
(amps)
60
60
60
60
50
50
50
50
50
50
Curtis 1244 Manual,
Rev. E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents