Multimode electronic motor controller
Table of Contents

Advertisement

2 — INSTALLATION & WIRING:
C A U T I O N
20
Misc. Features
not resumed until neutral (no direction) is selected or until the interlock switch
is cycled.
CAUTION:
The polarity of the
operation of the emergency reverse feature. The forward and reverse switches
and the
and
connections must be configured so that the vehicle drives
F1
F2
away from the operator when the emergency reverse button is pressed.
An optional wire connected directly to the emergency reverse switch
provides for broken wire protection when that feature is enabled by the OEM.
The emergency reverse check feature periodically pulses the emergency reverse
circuit to check for continuity in the wiring. If there is no continuity, controller
output is inhibited until the wiring fault is corrected. The emergency reverse
wiring check wire (see dotted line in Figure 13) should be connected to the
emergency reverse switch terminals and to Pin 22.
For information about the emergency reverse parameters, see Section 3:
Programmable Parameters.
and
connections will affect the
F1
F2
Curtis 1244 Manual,