Standard Control Wiring
Wiring for the input switches and contactors is shown in Figure 3; the connector
is shown in more detail below.
24-pin detail (see Fig. 3):
EMERGENCY
REVERSE
CHECK
(factory option)
24
23
22
12
11
10
HOUR
FORWARD
METER
COIL
REVERSE
RETURN
The main contactor coil must be wired directly to the controller as shown in
Figure 3. The controller can be programmed to check for welded or missing
main contactor faults and uses the main contactor coil driver output to remove
power from the controller and motor in the event of various other faults. if the
main contactor coil is not wired to Pin 17, the controller will not be able
to open the main contactor in serious fault conditions and the system will
therefore not meet eec safety requirements.
2 — INSTALLATION & WIRING:
ELECTRO-
AUX
MAGNETIC
CONTACTOR
BRAKE
DRIVER
DRIVER
REVERSE
SIGNAL
CONTACTOR
DRIVER
DRIVER
21
20
19
18
9
8
7
6
PEDAL
FAULT
SWITCH
2
FAULT
EMERGENCY
REVERSE
(walkies only)
2-WIRE
POT
POT
(5 kΩ)
LOW
MAIN
POT
WIPER
17
16
15
14
5
4
3
2
MODE
INTERLOCK
SELECT
2
MODE
KEYSWITCH
SELECT
1
INPUT (KSI)
1
Controller
POT
HIGH
13
1
9