Fig. 15,
cont'd
Effect of adjusting the
throttle max parameter
(Throttle Types 3 and 4).
Curtis 1244 Manual,
Rev. E
0.2V
0–5kΩ Throttle: Type 3
0
1.2V
(1.4kΩ)
1.2V
(1.4kΩ)
0.5V
(400Ω)
0.5V
(400Ω)
0–5V Wigwag Throttle: Type 4
0
0.5V
1.3V
(500Ω)
(1.3kΩ)
0.7V
1.3V
(700Ω)
1.3kΩ)
0.7V
(700Ω)
1.3V
(1.3kΩ)
KEY
Throttle
Controller
0%
Deadband
Output
The programmer displays the throttle max parameter as a percentage of
the active throttle voltage range. The throttle max parameter can be adjusted
from 100% to 60%, in 2% increments. The nominal throttle wiper voltage
range depends on the throttle type selected. See Table 1 (page 10) for the char-
acteristics of your selected throttle type.
3 — PROGRAMMABLE PARAMETERS:
3.0V
3.3V
(5.0kΩ)
3.0V
(4.5kΩ)
3.0V
(4.5kΩ)
2.7V
(3.9kΩ)
3.7V
(3.7kΩ)
3.7V
(3.7kΩ)
2.1V
2.9V
(2.1kΩ)
(2.9kΩ)
2.1V
2.9V
3.7V
(2.1kΩ)
(2.9kΩ)
(3.7kΩ)
Notes: Voltages shown are at the pot wiper relative to B-.
For throttle types 1 and 3, the deadband points are
defined in terms of the nominal 5kΩ pot resistance.
Using a pot of greater or lesser resistance will give
100%
different values for the deadband points.
60% Throttle Max
10% Deadband
Throttle Parameters
5V
100% Throttle Max
30% Deadband
90% Throttle Max
30% Deadband
90% Throttle Max
10% Deadband
60% Throttle Max
10% Deadband
5V
100% Throttle Max
30% Deadband
4.5V
(4.5kΩ)
90% Throttle Max
30% Deadband
4.3V
(4.3kΩ)
90% Throttle Max
10% Deadband
4.3V
(4.3kΩ)
60% Throttle Max
10% Deadband
33