Curtis 1244 User Manual page 37

Multimode electronic motor controller
Table of Contents

Advertisement

Fig. 14,
Effect of
cont'd
adjusting the throttle
deadband parameter
(Throttle Types 3 and 4).
Curtis 1244 Manual,
Rev. E
0.5V
0.2V
0–5kΩ Throttle: Type 3
0
1.2V
(1.4kΩ)
0.6V
(450Ω)
0.2V
(0Ω)
0–5V Wigwag Throttle: Type 4
0
0.5V
1.3V
(500Ω)
(1.3kΩ)
0.5V
(500Ω)
0.5V
(500Ω)
KEY
Throttle
Controller
0%
Deadband
Output
The programmer displays the throttle deadband parameter as a percent-
age of the nominal throttle wiper voltage range and is adjustable from 0% to
30%, in 2% increments. The default deadband setting is 10%. The nominal
throttle wiper voltage range depends on the throttle type selected. See Table 1
(page 10) for the characteristics of your selected throttle type.
3 — PROGRAMMABLE PARAMETERS:
3.3V
(5.0kΩ)
3.3V
(5.0kΩ)
3.3V
(5.0kΩ)
3.7V
(3.7kΩ)
2.1V
2.9V
(2.1kΩ)
(2.9kΩ)
2.5V
(2.5kΩ)
Notes: Voltages shown are at the pot wiper relative to B-.
For throttle types 1 and 3, the deadband points are
defined in terms of the nominal 5kΩ pot resistance.
Using a pot of greater or lesser resistance will give
100%
different values for the deadband points.
Throttle Max parameter set at 100%.
0% Deadband
Throttle Parameters
5V
30% Deadband
10% Deadband
0% Deadband
5V
30% Deadband
4.5V
(4.5kΩ)
10% Deadband
4.5V
(4.5kΩ)
0% Deadband
4.5V
(4.5kΩ)
31