7 DISPLAY
Analyzer menu screen
Menu screen
7.ACTIVE TEST
(Operation test)
8.VERSION
(Program version)
7.2.3.3 ANALYZER MENU Screen
Operating Procedure
Switch (1)
Display item
Screen No.
SWING SOL
STEERING
SOL
1/3
T/C RLY
ASC RLY
LIFT LWR
SOL
TILT SOL
2/3
TILT BWD
SOL
UNLOAD SOL (Unused)
OPTION RLY T/C interlock relay forced operation
BUZZER
3/3
SWG TEST
LMP
RELIEF SOL
DISPLAY
SAS/OPS
ECU
1/1
ENGINE ECU Engine controller program version
CAN BRIDGE (Unused)
Step 1
Enter the password on the general screen to display
the service function "MASK MENU" screen.
Step 2
Check that "1. ANALYZER" is selected (highlighted)
on the screen and press switch (4) (enter) to call the
"ANALYZER MENU" screen.
Switch (4)
Step 3
Select the menu with switch (1), and press (enter)
switch (4) to move to the screen of the selected item.
Description
Swing lock solenoid forced operation
Knob position compensation solenoid forced oper-
ation
Forward/reverse traveling cut-off relay forced op-
eration
(Unused)
Lift lowering lock solenoid forced operation
Tilt solenoid forced operation
Backward tilt lock solenoid forced operation
Warning buzzer forced operation
Swing lock operation check
Electromagnetic relief valve forced operation
Display program version
SAS/OPS controller program version
7-85