In/Out Monitor (4) "5.I/O Steering"; "I/O M.handling 7/7" - Toyota 8FGU15 Repair Manual

Hide thumbs Also See for 8FGU15:
Table of Contents

Advertisement

7-106

7.2.3.5.4 In/Out monitor (4) "5.I/O STEERING"

This function displays ON/OFF status of the knob position correction and other switches, and analog input
voltages from sensors.
Operation Procedure

▪ "I/O M.HANDLING 7/7"

RPRES:P port pressure sensor voltage (V), (MPa display)
Displays voltage value and pressure corresponding value
of P port pressure sensor.
4YE engine model:
Standard (No load): 0.5V to 4.5V
Increases the voltage value as a hydraulic load increases.
Except 4YE engine model:
RPRES: ---- = Always
RSOL:
Electromagnetic relief valve solenoid current (A)
Displays electromagnetic relief valve solenoid current.
Standard solenoid current (When operating material hand-
ling):  0.3A to 0.75A
MU:
Lift raising switch
Displays status of lift raising switch.
Refer to "I/O M.HANDLING 1/7"
Mini lever/Joystick vehicle:
MALL:Material handling operations switch
Displays status of any material handling operations switch.
Vehicle without material handling switches are OFF: 0
Vehicle with material handling swiches are ON: 1
NE:Engine speed (rpm)
Refer to "I/O ENGINE CTRL 1/5"
Switch (4): Returning to ANALYZER MENU screen
Step 1
Display the "ANALYZER MENU" screen.
7 DISPLAY

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents