7-102
Condition of the Seat/lever and Detected Values (USOL/LSOL/TSOL/BTSL/SEAT)
Seat condition
Lever condition
USOL
LSOL
STD lever
TSOL
vehicle
BTSL
SEAT
USOL
LSOL
Mini lever/
Joystick
TSOL
vehicle
BTSL
SEAT
Sitting on seat
Lift lever
Not oper-
ated
Raising
-
-
0 (= OFF) 0 (= OFF) 1 (= ON)
0 (= OFF) 0 (= OFF) 0 (= OFF) 1 (= ON)
0 (= OFF) 0 (= OFF) 0 (= OFF) 0 (= OFF) 1 (= ON)
1 (= ON)
1 (= ON)
-
-
0 (= OFF) 0 (= OFF) 1 (= ON)
0 (= OFF) 0 (= OFF) 0 (= OFF) 1 (= ON)
-
-
1 (= ON)
1 (= ON)
▪ "I/O M.HANDLING 2/7"
Tilt lever
Lowering
Forward tilt
-
-
0 (= OFF) 0 (= OFF) 0 (= OFF) 0 (= OFF)
1 (= ON)
1 (= ON)
-
-
0 (= OFF) 0 (= OFF) 0 (= OFF) 0 (= OFF)
-
-
1 (= ON)
1 (= ON)
MA: Tilt angle sensor voltage (V)
Displays the input voltage from the tilt angle sensor to the
controller.
Standard with mast in the vertical position: 1.1 to 4.2 V
Mast vertical → forward tilt: Input voltage decreases
Mast vertical → backward tilt: Input voltage increases
MH: Lifting height switch
PRES: Load sensor voltage (V), and MPa display
SWLK: (Unused)
SWTK: Automatic fork leveling stop switch
Displays states of automatic fork leveling stop switch.
SWTK: 0 = OFF
SWTK: 1 = ON
SWATS: T/C interlock relay
Display states of T/C interlock relay.
SWATS: 0 = Traveling not possible
SWATS: 1 = Traveling possible
Switch (4): To "I/O M.HANDLING 3/7" screen
Backward tilt
Low lifting
High lifting
height
height
-
-
0 (= OFF) 1 (= ON)
1 (= ON)
1 (= ON)
1 (= ON)
-
-
0 (= OFF) 1 (= ON)
-
-
1 (= ON)
1 (= ON)
7 DISPLAY
Leaving
seat
-
-
0 (= OFF)
0 (= OFF)
0 (= OFF)
-
0 (= OFF)
-
0 (= OFF)